SPS 366.0609 NoteNote: See the Wisconsin Uniform Plumbing Code, chs. SPS 382 to 387, for plumbing and water conservation provisions.
SPS 366.0609 HistoryHistory: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 16-094: renum. from 366.0509 and am. Register April 2018 No. 748, eff. 5-1-18; correction in (title) made under s. 13.92 (4) (b) 2., Stats., Register April 2018 No. 748.
SPS 366.0701SPS 366.0701Alterations. Substitute the following wording for the requirements in IEBC section 701.2: Conformance. An existing building or portion thereof may not be altered such that the building becomes less safe than was required in its existing condition.
SPS 366.0701 HistoryHistory: CR 16-094: cr. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.0702SPS 366.0702Building elements and materials.
SPS 366.0702(1)(1)Materials and methods. Substitute the following wording for the requirements in IEBC section 702.4: All new work shall comply with materials and methods requirements in the IBC, IECC, IFGC, IMC, and IPC, as applicable, that specify material standards, detail of installation and connection, joints, penetrations, and continuity of any element, component, or system in the building.
SPS 366.0702(2)(2)International fuel gas code. The requirements in IEBC section 702.4.1 are not included as part of chs. SPS 361 to 366.
SPS 366.0702 HistoryHistory: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: am. Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. from 366.0602 and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.0704SPS 366.0704Means of egress.
SPS 366.0704(1)(1)Alterations. Substitute the following wording for the requirements in IEBC section 704.1: Alterations shall be done in a manner that maintains the level of protection required for the means of egress prior to the alteration.
SPS 366.0704(2)(2)Stairway width. This is a department rule in addition to the requirements in IEBC section 704: Where installing an inclined platform lift or stairway chairlift, the clear-passage width shall be provided with the lift in the unfolded, usable position—except where an existing, previously approved lift is being replaced, the clear-passage width may remain as it was with the original lift in place, but it may not be reduced by the replacement.
SPS 366.0704 HistoryHistory: CR 14-020: cr. Register August 2014 No. 704, eff. 9-1-14; CR 16-094: cr. (title), (1), renum. (2) from 366.0604 and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.0804SPS 366.0804Automatic sprinkler systems. This is a department exception to the requirement in IEBC section 804.2: The installation or extension of an automatic sprinkler system may exclude the protection of combustible concealed spaces that are not accessible in existing buildings. This exclusion is also applicable to sprinkler systems triggered by changes of use or additions.
SPS 366.0804 HistoryHistory: CR 10-103: renum. from Comm 66.0701 and am. Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. from 366.0704 and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.0809SPS 366.0809Altered existing mechanical systems. The exception to the requirements in IEBC section 809.1 and the requirements in IEBC section 809.2 are not included as part of chs. SPS 361 to 366.
SPS 366.0809 HistoryHistory: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 16-094: renum. from 366.0709 and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.0810SPS 366.0810Minimum plumbing fixtures. Substitute the following wording for the requirements in IEBC section 810.1: Where the occupant load of a story is increased by more than 20 percent, plumbing fixtures for the story shall be provided in quantities specified in the IBC based on the increased occupant load.
SPS 366.0810 HistoryHistory: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 16-094: renum. from 366.07010 and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.0902SPS 366.0902Special use and occupancy.
SPS 366.0902(1)(1)Boiler and furnace equipment rooms. Substitute the following wording for the requirements, but not the exceptions, in IEBC section 902.1.2: Boiler and furnace equipment rooms. Boiler and furnace equipment rooms adjacent to or within Groups I-1, I-2, I-4, R-1, R-2, and R-4 occupancies shall be enclosed in compliance with IBC 509 heating equipment enclosure requirements.
SPS 366.0902(2)(2)Emergency controls. The requirements in IEBC section 902.2.1 are not included as part of chs. SPS 361 to 366.
SPS 366.0902 HistoryHistory: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 16-094: cr. (title), (1), renum. (2) from 366.0802 and am. Register April 2018 No. 748, eff. 5-1-18; correction in (1) made under s. 13.92 (4) (b) 7., Stats., Register October 2018 No. 754.
SPS 366.0903SPS 366.0903Building elements and materials. Substitute the following wording for the requirements in IEBC section 803.2.1: All existing interior vertical openings in the work area connecting two or more floors shall be enclosed with approved assemblies having a fire resistance rating of not less than one hour with approved opening protectives.
SPS 366.0903 HistoryHistory: CR 16-094: cr. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.0904SPS 366.0904Level 3 alterations fire protection.
SPS 366.0904(1)(1)Upholstered furniture. The requirement in IEBC section 904.1.3 condition 3 is not included as part of chs. SPS 361 to 366.
SPS 366.0904(2)(2)Fire alarm and detection systems. Substitute the requirements from 2009 IEBC section 804.2 for the requirements in IEBC section 904.2.
SPS 366.0904 HistoryHistory: CR 16-094: cr. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.0909SPS 366.0909Level 3 alterations plumbing. These are department rules in addition to the requirements in IEBC chapter 9:
SPS 366.0909(1)(1)Pursuant to s. 101.128, Stats., level 3 alterations within an existing facility where the public congregates shall necessitate that plumbing fixtures serving the work area be provided in a ratio of at least 2 water closets for females as to each water closet and urinal for the males.
SPS 366.0909(2)(a)(a) Under this section “facility where the public congregates” has the meaning has given in s. 101.128 (1) (b), Stats.
SPS 366.0909 NoteNote: Section 101.128 (1) (b), Stats., reads: “Facility where the public congregates” means any of the following that has a general capacity or a seating capacity of 500 or more persons:
SPS 366.0909 Note1. An amusement facility.
SPS 366.0909 Note2. A convention or trade hall or center.
SPS 366.0909 Note3. A specialty event center.
SPS 366.0909 Note4. A sports or entertainment arena, center or building.
SPS 366.0909 Note5. A stadium.
SPS 366.0909 Note6. An airport, bus terminal, train station or other transportation center.
SPS 366.0909(2)(b)(b) Under this section “alterations” has the meaning has given in s. 101.128 (1) (d), Stats., for “renovation”.
SPS 366.0909 NoteNote: Section 101.128 (1) (d), Stats., reads: “Renovation” means any structural remodeling, improvement or alteration of an existing facility where the public congregates. “Renovation” does not include any of the following:
SPS 366.0909 Note1. Reroofing.
SPS 366.0909 Note2. Cosmetic remodeling, including painting or the installation of wall covering, of paneling, of floor covering or of suspended ceilings.
SPS 366.0909 Note3. An alteration to an electrical or mechanical system.
SPS 366.0909 HistoryHistory: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 16-094: renum. from 366.0809 and am. (intro.) REgister April 2018 No. 748, eff. 5-1-18; correction in (title) made under s. 13.92 (4) (b) 2., Stats., Register April 2018 No. 748.
SPS 366.1001SPS 366.1001Change of occupancy.
SPS 366.1001(1)(1)change of occupancy approval. Substitute the following wording for the requirements in IEBC section 1001.2: A change of occupancy or a change of occupancy within a space where there is a different fire protection system threshold requirement in IBC chapter 9 may not be made to any structure without the approval of the code official. An increased occupant load may trigger additional means of egress or fire protection requirements.
SPS 366.1001(2)(2)Change of occupancy classification. This is a department rule in addition to the requirements in IEBC section 1001.2.2: Buildings undergoing a change in occupancy that would result in an increase in demand for either fossil fuel or electrical energy shall comply with the IECC.
SPS 366.1001(3)(3)Certification of occupancy required. The requirements in IEBC section 1001.3 are not included as part of chs. SPS 361 to 366.
SPS 366.1001 HistoryHistory: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: am. (1) Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. (title), (1) to (3) from 366.0901 (title), (1) to (3) and am., renum. (4) to SPS 366.1012 Register April 2018 No. 748, eff. 5-1-18.
SPS 366.1010SPS 366.1010Change of occupancy plumbing. Substitute the following wording for the requirements in IEBC section 1010: Where the occupant load of a story is increased by more than 20 percent, plumbing fixtures for the story shall be provided in quantities specified in the IBC based on the increased occupant load.
SPS 366.1010 HistoryHistory: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: renum. from Comm 66.0910 Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. from 366.0912 and am. Register April 2018 No. 748, eff. 5-1-18; correction in (title) made under s. 13.92 (4) (b) 2., Stats., Register April 2018 No. 748.
SPS 366.1011SPS 366.1011Other requirements.
SPS 366.1011(1)(1)Elevator recall. This is a department rule in addition to the requirements in IEBC section 1011: At least one existing elevator shall be provided with emergency recall operation and emergency in-car operation complying with ch. SPS 318 when an existing building or structure that is greater than 60 feet in height is changed to include a Group R-1 or R-2 occupancy.
SPS 366.1011(2)(2)Carbon monoxide alarms. This is a department rule in addition to the requirements in IEBC section 1011: A building or a portion of a building changed to be or include a residential building as defined under s. 101.149 (1) (b), Stats., shall be provided with carbon monoxide alarms or detectors in accordance with s. SPS 362.0915.
SPS 366.1011 HistoryHistory: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; EmR0826: emerg. renum. to be (1), cr. (1) (title) and (2), eff. 10-1-08; CR 08-085: renum. to be (1), cr. (1) (title) and (2) Register May 2009 No. 641, eff. 6-1-09; correction in (1), (2) made under s. 13.92 (4) (b) 7., Stats., Register December 2011 No. 672; CR 16-094: renum. from 366.0911 and am. Register April 2018 No. 748, eff. 5-1-18; correction in (2) under s. 13.92 (4) (b) 7., Stats., Register April 2018 No. 748.
SPS 366.1012SPS 366.1012Standpipe systems. This is a department rule in addition to the requirements in IEBC section 1012.2: Standpipe systems shall be provided in existing buildings and structures or portions of existing buildings and structures in accordance with IBC chapter 9 when existing buildings or structures that are greater than 60 feet in height are changed to include a Group R-1 or R-2 occupancy.
SPS 366.1012 HistoryHistory: CR 16-094: renum. SPS 366.0901 (4) and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.1102SPS 366.1102Heights and areas.
SPS 366.1102(1)(1)Area limitations. This is a department exception in addition to the exception in IEBC section 1102.2: Buildings meeting the legacy Wisconsin unlimited area provisions are allowed to have unlimited area additions per the current code without a separating firewall.
SPS 366.1102(2)(2)Fire protection systems. This is a department exception to the requirements in IEBC section 1102.3: An automatic sprinkler system is not required for additions to individual dwelling units within existing townhouses that are not already protected with an automatic sprinkler system.
SPS 366.1102 HistoryHistory: CR 10-103: cr. Register August 2011 No. 668, eff. 9-1-11; CR 16-094: cr. (title), (1), renum. (2) from 366.1002 and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.1201SPS 366.1201Historic buildings.
SPS 366.1201(1)(1)Scope. This is a department rule in addition to the requirements in IEBC section 1201.1: Any historic building is exempt from the energy requirements of chs. SPS 361 to 366.
SPS 366.1201(2)(2)Report. The requirements in IEBC section 1202.2 are not included as part of chs. SPS 361 to 366.
SPS 366.1201 HistoryHistory: CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; CR 10-103: renum. (1) to be (2), (2) to be Comm 66.1105 and am. (2) (title), cr. (1) Register August 2011 No. 668, eff. 9-1-11; CR 16-094: renum. from 366.1101 and am. Register April 2018 No. 748, eff. 5-1-18.
SPS 366.1204SPS 366.1204Historic buildings alterations. Historic buildings are not required to comply with the IECC for building envelope compliance except as follows:
SPS 366.1204(1)(1)Existing ceiling, wall, or floor cavities exposed during alterations shall be filled with insulation.
SPS 366.1204(2)(2)All replacement skylight, window, and/or door assemblies shall meet the minimum code requirements of the IECC unless specifically designed to address unique aesthetics associated with the historic nature of the building. Glass only replacements in an existing sash and frame are exempt from the application of the IECC.
SPS 366.1204(3)(3)Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing so as to meet the minimum insulation required by the IECC, or shall provide insulation to the greatest extent possible.
SPS 366.1204 HistoryHistory: CR 16-094: cr. Register April 2018 No. 748, eff. 5-1-18; correction in (title) made under s. 13.92 (4) (b) 2., Stats., Register April 2018 No. 748.
SPS 366.1205SPS 366.1205Exhibit buildings. These are department rules in addition to the requirements in IEBC section 1205: Historic buildings to be used as exhibit buildings shall comply with all of the following requirements:
SPS 366.1205(1)(1)The building shall be open to the public only under the supervision of a tour guide.
SPS 366.1205(2)(2)The building may not be lived in, slept in or worked in, except for the purpose of demonstrating to the public how people lived in a particular era.
SPS 366.1205(3)(3)Smoking is prohibited in the building.
SPS 366.1205(4)(4)Open flame equipment may not be used in the building, except for fire places and other mechanical equipment original to the building.
SPS 366.1205(5)(5)Fire extinguishers shall be installed in exhibit buildings and may be located in a nonconspicuous location but accessible to the occupants.
SPS 366.1205(6)(a)(a) At least one smoke detector shall be provided for each 1,200 square feet of floor area with a minimum of one smoke detector per floor level.
SPS 366.1205(6)(b)1.1. Except as specified in subd. 2., where electricity is provided in the exhibit building, the smoke detectors shall be connected to the electrical power.
SPS 366.1205(6)(b)2.2. Where no electrical power is provided to an exhibit building, the smoke detectors shall be of a battery type.
SPS 366.1205(6)(b)3.3. Smoke detectors shall be tested weekly.
SPS 366.1205(7)(7)Exhibit buildings provided with only one means of egress shall be restricted to a total capacity of 12 people, and not more than 6 people may be located above or below the first floor at any one time.
SPS 366.1205(8)(8)Stairways without 6-foot, 4-inch vertical headroom clearance shall have signs posted warning occupants of the headroom clearance available.
SPS 366.1205(9)(9)Exit signs shall be provided in accordance with the prevailing code in exhibit buildings occupied prior to ½-hour before sunrise and ½-hour after sunset and in all areas not provided with natural lighting.
SPS 366.1205 HistoryHistory: CR 10-103: renum. from Comm 66.1101 (2) Register August 2011 No. 668, eff. 9-1-11; correction in (b) 1. made under s. 13.92 (4) (b) 7., Stats., Register August 2011 No. 668; CR 16-094: renum. from 366.1105 and am. (intro.) Register April 2018 No. 748, eff. 5-1-18.
SPS 366.1401SPS 366.1401Performance compliance methods.
SPS 366.1401(1)(1)Applicability. Substitute the following wording for the requirements in IEBC section 1401.2: The provisions of sections 1401.2.1 through 1401.2.5 shall apply to existing occupancies that will continue to be, or are proposed to be, in Groups A, B, E, F, M, R, and S. These provisions may not apply to buildings with occupancies in Group H or Group I.